EICR remedial work in Harrow
If an EICR has come back unsatisfactory, we carry out the remedial work in Harrow and the neighbouring towns: the C1 and C2 items, plus any further investigation the report asks for. We price each observation against your report, complete the work and give you the certificate you need to confirm to your tenants and the council that it has been done.
- Priced item by item
- Certificate for the work
- Reports from any electrician
What remedial work usually involves
Most unsatisfactory reports come down to a handful of familiar problems:
- circuits without RCD protection where current rules need it, such as sockets that could supply equipment outdoors
- missing or undersized main protective bonding to the gas and water pipes
- damaged sockets, switches or fittings with live parts exposed or loose
- signs of overheating at connections or in the consumer unit
- a consumer unit that is damaged, unsuitable or poorly fitted
Each one is a specific fix. Your report says which apply and where.
The 28-day deadline for landlords
The regulations give a landlord 28 days from the inspection, or a shorter period if the report sets one, to have remedial work and further investigation done by a qualified person. A C1 means danger is present and needs immediate action, so the inspector should make it safe on the spot, typically by isolating the circuit. Once the work is complete, you have 28 days to give written confirmation to your tenants and the council. The certificate for the work (an Electrical Installation Certificate or a Minor Works certificate) is accepted as that confirmation.
Got a report from another electrician?
Send it over. You can use any qualified electrician for remedial work, not only the one who did the inspection. We check each observation on site before fixing it, and if we read a code differently we explain why, with reference to the regulation it concerns, so you can decide with the facts in front of you.
Repair or bigger work?
When several C2 items trace back to an old board, replacing the consumer unit can cost less overall than patching around it. When low insulation readings run across many circuits, the cable itself is the problem and a rewire, full or partial, is the lasting answer. We tell you which situation you are in and price both routes if both are reasonable.
What affects the price
The number and type of observations set most of the cost. Replacing a damaged socket is a small job; adding RCD protection to several circuits, or running new bonding conductors through finished rooms, takes longer. Access, the parts needed and whether a fix involves a new circuit all play a part. You get a price for each item, so you can see where the money goes.
Common questions
Does the whole EICR need redoing after remedial work?
No. The work gets its own certificate, which the government guidance accepts as written confirmation. A new full report is not needed.
Do I have to fix C3 items?
No. C3 is a recommendation, not a requirement, and does not make a report unsatisfactory.
What if the report says FI?
FI means the inspector found something they could not fully assess. Under the April 2026 wiring rules an FI no longer makes a report unsatisfactory on its own, but the government guidance says landlords must still have it investigated, within the same 28 days.
Sources
Get a price
Ring us, or leave your number and we will call back with a price.
- Postcode and property type
- Number of bedrooms
- Any outbuildings or a second board
- Your deadline, if you have one
EICR remedial work across north-west London
We provide EICR remedial work in Harrow and the neighbouring towns. Choose yours for local licensing and housing notes.
Useful reading
Failed EICR: what to do next
Six steps from an unsatisfactory report to a closed file.
EICR codes explained: C1, C2, C3 and FI
What each code means and which ones fail a report.
Landlord electrical safety rules in England
Every deadline and duty in one place.
Other services in this group
Consumer unit replacement
Old fuse boxes swapped for a metal board with RCD protection.
House rewiring
Full and partial rewires when repairs no longer add up.
Smoke and heat alarms
Mains-wired, interlinked alarms for lets and family homes.
Also from Harrow EICR
Landlord EICRs
The five-yearly inspection every private let in England needs.
Home electrical inspections
For homes you own, are buying or are about to renovate.
HMO and commercial EICRs
Shared houses, flats above shops and small business premises.
PAT testing
Appliance checks for furnished lets, HMOs and workplaces.
Get a price