Landlord EICRs in Harrow
We carry out landlord EICRs (electrical installation condition reports) on rented homes in Harrow and across north-west London. The inspection checks the fixed wiring, consumer unit, earthing, sockets, switches and fittings, and the report states whether the installation is satisfactory for continued use. It is the document the electrical safety regulations require you to hold at least every five years and to give to your tenants.
- Due at least every 5 years
- Copy ready for each tenant
- Remedial work priced separately
What a landlord EICR involves
An EICR has two halves. The first is inspection: the electrician looks over the consumer unit, the earthing and bonding to gas and water pipes, and opens up a sample of sockets, switches and light fittings to check the connections and the cable behind them. The second is testing: every circuit is tested with calibrated instruments for continuity, insulation resistance, polarity, earth fault loop impedance and, where fitted, RCD operation.
The results go onto a report with a schedule of test results for each circuit, a list of observations, each with a classification code, and an overall verdict of satisfactory or unsatisfactory. You receive the report to keep and to pass on.
What the law asks of a landlord
Under the Electrical Safety Standards regulations, a private landlord in England must have the installation inspected and tested by a qualified person at least every five years, or sooner if the last report says so. Our inspections are carried out as an NICEIC Approved Contractor. The report then has to reach the right people on time:
- each existing tenant within 28 days of the inspection
- a new tenant before they move in
- a prospective tenant within 28 days of asking in writing
- the local council within 7 days of a written request
You keep the report until the next inspection and give a copy to the next inspector. The government guidance says a council can impose a financial penalty of up to £40,000 for a breach. The full list is in our landlord electrical safety rules guide.
When the report comes back unsatisfactory
A report is unsatisfactory when it contains any C1 (danger present) or C2 (potentially dangerous) observation. The regulations then give you 28 days, or less if the report sets a shorter time, to have the remedial work or any further investigation done by a qualified person. Within 28 days of the work being finished you must confirm it in writing to your tenants and the council, usually by sending the certificate for the work.
We price remedial work as a separate quote set out observation by observation, so you can see what each fix is for and compare it with another electrician’s price if you want to.
Access and tenants
The power has to go off circuit by circuit during testing, so tenants need notice. Ask them to expect the fridge, freezer, broadband router and any home office to lose power for short spells, and tell us in advance about anything that must stay on, such as medical equipment. If you are not there, we can arrange access through the tenant or your letting agent and send the report to both of you.
What affects the price of a landlord EICR
The time an inspection takes depends mostly on the number of circuits, not the number of bedrooms. A flat with six circuits is quicker than a house with a second consumer unit, an extension, a garage and a garden office. Unlabelled or hard-to-reach boards, locked rooms and tenants’ furniture against sockets also add time. Ask for a price with the property type and postcode, and say whether you want PAT testing done on the same visit. Our guide to what an EICR costs explains how to compare quotes.
Common questions
How long is a landlord EICR valid?
Up to five years. If the inspector sets a shorter date on the report, for example because the installation is old or in poor condition, the shorter date is the one the law applies.
Does a new tenancy need a new EICR?
No. A report remains valid for its full period across tenancies. The new tenant must receive a copy before moving in.
Do I need to be at the property?
No. Many landlords give access through the tenant or the letting agent, and the report is sent to them by email.
Does a C3 mean I have to do the work?
No. C3 means improvement recommended. The government guidance says it does not require remedial work, although acting on it makes the property safer.
Are you NICEIC registered?
Yes. We are an NICEIC Approved Contractor and an NICEIC Domestic Installer (Part P).
Is an EICR the same as a landlord electrical safety certificate?
Yes. "Electrical safety certificate" and "landlord electrical certificate" are the everyday names. The document itself is the electrical installation condition report.
Sources
Get a price
Ring us, or leave your number and we will call back with a price.
- Postcode and property type
- Number of bedrooms
- Any outbuildings or a second board
- Your deadline, if you have one
Landlord EICRs across north-west London
We provide landlord EICRs in Harrow and the neighbouring towns. Choose yours for local licensing and housing notes.
Useful reading
Landlord electrical safety rules in England
Every deadline and duty in one place.
EICR codes explained: C1, C2, C3 and FI
What each code means and which ones fail a report.
Failed EICR: what to do next
Six steps from an unsatisfactory report to a closed file.
Other services in this group
Home electrical inspections
For homes you own, are buying or are about to renovate.
HMO and commercial EICRs
Shared houses, flats above shops and small business premises.
PAT testing
Appliance checks for furnished lets, HMOs and workplaces.
Also from Harrow EICR
EICR remedial work
Fixing C1, C2 and FI items so the report can be closed off.
Consumer unit replacement
Old fuse boxes swapped for a metal board with RCD protection.
House rewiring
Full and partial rewires when repairs no longer add up.
Smoke and heat alarms
Mains-wired, interlinked alarms for lets and family homes.
Get a price
Leave your number and we will ring back with a price and the next available times. Or ring 020 8194 2001.