HMO and commercial EICRs in Harrow
We inspect and test the electrics in houses in multiple occupation (HMOs), flats above shops and small commercial premises in Harrow, Brent, Barnet and south Hertfordshire. You get one EICR covering every letting room, communal area and landlord supply, ready to send with a licence application or to the council when it asks.
- Every room and communal area
- For licence applications
- Shops and offices too
Why HMOs get closer attention
More people sharing a building means more appliances, more cooking and more extension leads, and a fault affects every household in it. The Electrical Safety Standards regulations apply to HMOs just as they do to single lets, so the five-year EICR and the 28-day rules for copies and remedial work all apply.
A licensed HMO carries further conditions under the Housing Act 2004. The licence holder must keep every electrical installation in proper working order and safe for continued use, keep any appliances they supply in a safe condition, fit a smoke alarm on each storey with living accommodation, and give the council a declaration on any of these when asked.
Licensing in Harrow, Brent and Barnet
Larger HMOs, with five or more people from two or more households, need a mandatory licence everywhere. For smaller ones the rules differ by borough. Harrow licensed them across the whole borough from 6 August 2021 until the scheme ended on 5 August 2026, and consulted in early 2026 on renewing it. Barnet has licensed them borough-wide since 27 October 2022. Brent went further: since 2 February 2026 almost every privately rented home in the borough needs a licence, including HMOs with three or four tenants. Barnet also consulted in 2026 on licensing all private lets in ten wards. A licence does not change the electrical rules, but it does mean the council knows the property and can ask for the report at any time. Our area pages cover each borough.
Arc fault detection in HMOs
The wiring regulations, BS 7671, call for arc fault detection devices (AFDDs) on socket-outlet circuits rated up to 32 A in HMOs, care homes, purpose-built student accommodation and tall residential buildings. An AFDD spots the electrical arcing a damaged cable or loose connection produces and switches the circuit off before it can start a fire. The requirement applies when new work is designed, so it matters most when an HMO gets a new consumer unit or new socket circuits, and we include AFDDs in those quotes.
Shops, offices and other workplaces
The Electricity at Work Regulations 1989 require electrical systems at work to be maintained so they are safe, but, as the HSE explains, they do not set how or how often that is checked. A current EICR is how most small businesses show they have done it, and insurers, landlords and leases often ask to see one. For a flat above a shop, the flat’s own installation needs the landlord EICR; the shop’s supply is a separate report for whoever is responsible for it.
What affects the price
For an HMO or a business, the number of distribution boards and circuits matters most, followed by the number of rooms, communal areas and outbuildings, and whether every room can be opened on the day. A three-phase supply or sub-boards in different parts of the building add time. We price after a short conversation about the building, so the quote reflects what is actually there.
Common questions
Do HMOs need an EICR more often than every five years?
The regulations set five years as the longest interval. The inspector can set a shorter one on the report, and that shorter date then applies.
Can you test the appliances in the HMO as well?
Yes, the ones you supply as landlord. Tenants are responsible for their own. See PAT testing.
Is a commercial EICR a legal requirement?
The law requires workplace electrics to be kept safe but sets no fixed date. A current report is the usual evidence, and insurers often ask for one.
Sources
- legislation.gov.uk: Housing Act 2004, Schedule 4 (licence conditions)
- GOV.UK: Electrical safety standards in the private and social rented sectors, guidance (November 2025)
- NICEIC: BS 7671:2018+A4:2026 explained
- HSE: portable appliance testing, frequently asked questions
- Harrow Council: additional HMO licensing scheme
- London Property Licensing: Harrow and Barnet scheme status (September 2026)
- London Property Licensing: Barnet scheme status
- Brent Council: all landlords in Brent must now be licensed (February 2026)
- NRLA: licensing update, July 2026 (Harrow and Barnet)
Get a price
Ring us, or leave your number and we will call back with a price.
- Postcode and property type
- Number of bedrooms
- Any outbuildings or a second board
- Your deadline, if you have one
HMO and commercial EICRs across north-west London
We provide HMO and commercial EICRs in Harrow and the neighbouring towns. Choose yours for local licensing and housing notes.
Useful reading
Landlord electrical safety rules in England
Every deadline and duty in one place.
EICR codes explained: C1, C2, C3 and FI
What each code means and which ones fail a report.
What an EICR costs, and why quotes differ
What sets the price and how to compare quotes fairly.
Other services in this group
Landlord EICRs
The five-yearly inspection every private let in England needs.
Home electrical inspections
For homes you own, are buying or are about to renovate.
PAT testing
Appliance checks for furnished lets, HMOs and workplaces.
Also from Harrow EICR
EICR remedial work
Fixing C1, C2 and FI items so the report can be closed off.
Consumer unit replacement
Old fuse boxes swapped for a metal board with RCD protection.
House rewiring
Full and partial rewires when repairs no longer add up.
Smoke and heat alarms
Mains-wired, interlinked alarms for lets and family homes.
Get a price
Leave your number and we will ring back with a price and the next available times. Or ring 020 8194 2001.